SendCutSend for Commercial Users

How to use your Net30 account and create a Formal Quote with SendCutSend

Starting an Order Using Your Net30 Terms Account

If you don’t have a Net30 account, click here to learn about qualifications and how to set one up.

When you have your Net30 account created, you can start ordering parts from SendCutSend using your Net30 terms account. To do this, once your cart is complete, click the “Continue” button at the bottom of your screen.

This will prompt you to add shipping and billing information for your project as well as a PO number.

Please note: tax exemption is offered, but your account will need to be set up for it. Please see the Tax Exempt section at the bottom of this page for more information.

At the payment screen, click “Pay with Terms” to use your Net30 account.

If you do not see a “Pay with Terms” option, please verify that you are signed into your SendCutSend account and reach out to us if the problem persists.

Creating a Formal Quote for Your Project

We created the Formal Quote feature for times when a project needs to be sent to a purchasing department for approval and funding, as well as for occasions when a Net30 account will be used but a PO number has not yet been generated.

After you’ve added all of the items you need to your shopping cart, you’ll be taken through the checkout process. On the Payment step, you will click the Create Formal Quote button below your payment options.

You’ll have the option to insert a PO number or project name for the Formal Quote. If a PO number is not available at the time of the quote’s creation, it will need to be added at the time the payment is applied to the account.

You can create your Formal Quote without a PO number.

A Formal Quote creates a PDF quote of your order with a purchase link at the bottom of it as well as a direct payment link that you can send to your colleagues. Anyone can purchase the parts on a Formal Quote, but the billing and shipping information cannot be changed once the quote has been created.

When the purchasing link is clicked by someone with a Net30 terms account, a PO number can be added to the project, and the order can be initiated by clicking the “Pay with Terms” option.

Please note: if the Formal Quote was created by someone outside of your Net30 terms account group, it will not be possible for this quote to be funded using your Net30 terms. If this is the case with your project, please reach out to us and we will create a new quote for you.

How to Use Formal Quotes Without Net30 Terms

Formal Quotes can be used by customers who don’t have Net30 terms, too! The process will be the same, except the credit card or Paypal information will need to be entered at the payment screen to start the order.

Shipping and billing details on a Formal Quote cannot be changed unless the project is requoted. To requote a project, go to the “Orders” tab, find the project associated with your quote, and click “Requote.”

A Formal Quote is valid for 30 days from the date it was created, and after that time, it will need to be requoted.

Please note that generating a Formal Quote will not start an order: a payment method must be selected to begin production.  When the order has been started, the user who created the Formal Quote will be notified by email or SMS message that the order has been started. This person will remain the point of contact for the order if we have follow up questions, and they’ll receive production and shipping updates.

Tax Exemption

You can make tax-exempt purchases at sendcutsend.com. Before you place your order or create a Formal Quote, we’ll need to have your tax form on file and connected to your user account.

You can send your tax form to our Support team and we will create an option on your account that allows you to enable tax-exempt purchases.

For resellers and tax exempt organizations, we can refund tax charged on orders if the refund request is submitted within the same calendar month the order was placed. Please be sure to request tax exempt status for your account before placing an order.

Important Documents

SendCutSend w9

SendCutSend Payment Information

If you have any questions, feel free to contact us. We typically respond to emails within 4 hours, though we strive to respond even faster.

Thank you for your business and we look forward to a great working relationship with you in the future!

Start your first SendCutSend project today!

Upload your CAD design or use our parts builder and get a free instant quote on your custom laser cut parts, all delivered to your door in a matter of days.
No CAD File? No Problem! Send your sketch or template to our Design Services team. Starting at $49.

We proudly use hardware by PEM

Flush stud, M8 x 1.25, .472" Zinc plus Clear Chromate

Aluminum: 5052, 6061, 7075 Steel: Mild

SKUFH-M8-12
Thread SizeM8 x 1.25
Hole size in sheet (+0.003/-.0.000).315″
Minimum sheet thickness0.094″
Maximum sheet thickness.347″
Fastener materialSteel
Minimum distance hole C/L to edge0.378″
Minimum distance between two of the same hardware.567″
Recommended panel materialSteel/Aluminum
Coating typeZinc
Length.472″
Aluminum material ranges (5052, 6061, 7075)0.100″-0.250″
Steel material ranges (CRS, HRPO, HR)0.104″-0.250″

Get an Instant Quote for Waterjet Cutting

We proudly use hardware by PEM

Flush Standoff, 4-40, .250" Zinc plus Clear Chromate

Aluminum: 5052, 6061, 7075 Steel: Mild, G30

SKUSO-440-8
Thread Size4-40 x .250″
Hole size in sheet (+0.003/-.0.000).168″
Minimum sheet thickness0.040″
Maximum sheet thickness.125″
Fastener materialSteel
Minimum distance hole C/L to edge0.230″
When determining the distance between two or more fasteners, you can calculate the distance by the formula, C/L to edge + 1/2 the diameter of the second mounting hole..345″
Recommended panel materialSteel/Aluminum
Coating typeZinc
Length.250″
Aluminum material ranges (5052, 6061, 7075)0.040″-0.125″
Steel material ranges (CRS, HRPO, HR)0.048″-0.119″

We proudly use hardware by PEM

Flush Standoff, 4-40, .250" Passivated

Stainless Steel: 304, 316

SKUSO4-440-8
Thread Size440
Hole size in sheet (+0.003/-.0.000).166″
Minimum sheet thickness0.04″
Maximum sheet thickness.125″
Fastener material400 Stainless Steel
Minimum distance hole C/L to edge0.230″
When determining the distance between two or more fasteners, you can calculate the distance by the formula, C/L to edge + 1/2 the diameter of the second mounting hole. Example shown with x2 of the same hardware..313″
Recommended panel materialStainless Steel
Coating typePassivated
Length.250″
304 Stainless Steel material ranges0.048″-0.125″
316 Stainless Steel material ranges0.060″-0.125″